HRSG Projects |
 |
 |
| Goat Rock, The Southern Company Alabama, Florida, USA |
IDS, Engineering Subcontractor to Deltak LLC., for the Design &
Installation of four (4), Three Pressure Level, Heat Recovery Steam Generator (HRSG)
Boiler units for The Southern Company, (3) located in Alabama, and (1) in
Florida, USA.
IDS provided Deltak with Piping Layout & Design, Stress Analysis and Pipe
Support Engineering services for all of the Code and Non-Code Piping systems for
the HRSG Boiler island. IDS also provided Design/Drafting services including;
developing all required Piping 3-D Models, Piping Arrangement & Installation
Drawings, Isometric Detail Drawings and all associated Pipe Support Detail
Drawings.
The HRSG Pressure Piping Systems designed and engineered by IDS included; the
High Pressure (HP), Intermediate Pressure (IP), Low Pressure (LP), Reheat Steam
System and Interconnecting Steam Piping Systems. Also, Boiler Feedwater and
Recirculation Water systems, Steam Drum Trim Piping, Vent Stack and Silencer
Piping and all Small Bore Vent & Drain Trim Piping. Auxiliary Systems included;
the SCR Ammonia Piping, Natural Gas Piping, Instrument Air and Cooling Air
Piping System.
IDS performed all of the required Code Calculations, Piping Stress Analysis and
Pipe Support Engineering for all of the Piping Systems in accordance with the
applicable ASME Boiler Codes and Building Codes, including but not limited to;
Section I, Section VIII, B31.1, B31.3 and International Building Code (2000
IBC). IDS also developed and provided all required load calculations including;
Seismic & Wind loads, Thermal Expansion Movements, Loads to Foundations,
Structural Steel, Platforms, as well as, determining all Pipe Support loads,
locations and designs. |
| |
| South Houston Green Power Company - Texas City, Texas, USA |
IDS, Engineering Subcontractor to Deltak LLC., for the installation of three (3), Two Pressure Level, Heat Recovery Steam Generator (HRSG) Boiler units with Selective Catalytic Reactor Systems (SCR), for South Houston Green Power Company, located in Texas City, Texas, USA.
IDS provided Deltak with Piping Layout & Design, Stress Analysis and Pipe Support Engineering services for all of the Code and Non-Code Piping systems for the HRSG Boiler island. IDS also provided Design/Drafting services including; developing all required Piping 3-D Models, Piping Arrangement & Installation Drawings, Shop Fabrication Detail Drawings and all associated Pipe Support Detail Drawings.
The HRSG Pressure Piping Systems designed and engineered by IDS included; the High Pressure (HP), Low Pressure (LP), and Interconnecting Steam Piping Systems. Also, Boiler Feedwater and Recirculation Water systems, Steam Drum Trim Piping, Vent Stack and Silencer Piping and all Small Bore Vent & Drain Trim Piping. Auxiliary Systems included; the SCR Ammonia Piping, Natural Gas Piping, Instrument Air and Cooling Air Piping System.
IDS performed all of the required Code Calculations, Piping Stress Analysis and Pipe Support Engineering for all of the Piping Systems in accordance with the applicable ASME Boiler Codes and Building Codes, including but not limited to; Section I, Section VIII, B31.1, B31.3 and International Building Code (2000 IBC). IDS also developed and provided all required load calculations including; Seismic & Wind loads, Thermal Expansion Movements, Loads to Foundations, Structural Steel, Platforms, as well as, determining all Pipe Support loads, locations and designs. |
| |
| I.C.A. Flour Daniel, Cantarell, Atasta, Campeche, Mexico |
IDS, Engineering Subcontractor to ALSTOM POWER Inc. (formerly, ABB
Combustion Engineering Inc.), for the installation of four (4), Two Pressure
Level Heat Recovery Steam Generator (HRSG) Boiler units for Fluor Daniel/PEMEX,
located in Campeche, Mexico.
IDS provided ALSTOM with Piping Layout & Design, Stress Analysis and Pipe
Support Engineering services for all of the Code Piping systems for the HRSG
Boiler island. IDS also provided Design/Drafting services including; developing
all required Piping Arrangement & Installation Drawings, Isometric Detail
Drawings and all associated Pipe Support Detail Drawings.
The HRSG Pressure Piping Systems designed and engineered by IDS included; the
High Pressure (HP), Low Pressure (LP) and Interconnecting Steam Piping Systems.
Also, Boiler Feedwater and Recirculation Water systems, Boiler Make-Up Water
system, Demineralization Water system, Steam Drum Trim Piping, Vent Stack and
Silencer Piping and all Small Bore Vent & Drain Trim Piping.
IDS performed all of the required Code Calculations, Piping Stress Analysis and
Pipe Support Engineering for all of the Piping Systems in accordance with the
applicable ASME Boiler Codes and Standards, including but not limited to;
Section I, Section VIII, B31.1 and B31.3. IDS also developed and provided all
required load calculations including; Seismic & Wind loads, Thermal Expansion
Movements, Loads to Foundations, Structural Steel, Platforms, as well as,
determining all Pipe Support loads, locations and designs |
|
|
|
|
|
|
 |
| |
|